山东创图建筑装饰工程有限公司 山东创图建筑装饰工程有限公司
加工技术热线:18660816658
  • 您当前位置: 首页>>新闻动态>>常见问题浅议防火板隔墙应用的方法!

    常见问题

    浅议防火板隔墙应用的方法!

    来源:https://www.fumeijia.net/ 日期:2020-12-25 发布人:admin
    使用的具体步骤:
    The specific steps are as follows:
    1.防火板材:一般情况下建议用6mm厚度以上的玻镁板作隔墙板。
    1. Fireproof board: generally, it is recommended to use glass magnesium board with a thickness of more than 6 mm as partition board.
    2.配件:6mm以上的板材固定在框架龙骨上,要用3.5200mm的沉头螺钉固定,钉头低于板面0.5mm,以便保证饰面平整。
    2. Accessories: the plate with a diameter of more than 6 mm is fixed on the frame keel with a 3.5200 mm countersunk screw. The nail head is 0.5 mm lower than the plate surface to ensure the smooth finish.
    3.安装:开始安装时,必须标好龙骨的准确位置,并作好记号。竖龙骨距离为450-600mm,墙体的连接处和门窗两侧安装时要装附加龙骨,如墙体高度大于2440mm时,须在板材连接处加装支撑龙骨。
    3. Installation: at the beginning of installation, the accurate position of keel must be marked and marked. The center distance of vertical keel is 450-600mm. Additional keel shall be installed at the connection of wall and both sides of doors and windows. If the wall height is greater than 2440 mm, support keel shall be installed at the connection of plate.
                       富美家防火板
    4.板距:相临板材之间留缝距4-6mm,板材与地面之间必须留有5mm的间隙,螺钉安装距为150mm,距板边10mm,距离板角30mm。
    4. Plate distance: the seam distance between adjacent plates is 4-6 mm, the gap between plates and the ground must be 5 mm, the screw installation center distance is 150 mm, the distance from plate edge is 10 mm, and the distance from plate angle is 30 mm.
    5.吊挂:卫生间或厨房间等吊挂重物处,必须用木板或龙骨加固,以免板材受到破坏。
    5. Hanging: the places where heavy objects are hung in toilets or kitchens must be reinforced with wooden boards or keels to avoid damage to the boards.
    6.接缝处理:在安装时板材与板材留有间隙4-6mm,用107胶水或强力胶调匀后用刮刀涂抹板材及缝隙处,然后用纸带或风格带粘贴压平。
    6. Joint treatment: during installation, there is a gap of 4-6mm between the plates. After mixing with 107 glue or strong glue, smear the plate and the gap with a scraper, and then paste and flatten it with paper tape or style tape.
    7.涂料装饰:可以用喷涂、刷涂或滚涂,但刷涂时必须参看涂料的有关说明。
    7. Coating decoration: spray, brush or roll coating can be used, but the relevant instructions of the coating must be referred to when brushing.
    8.装饰面贴瓷砖:在浴室、卫生间、厨房、地下室等潮湿区域安装时,如需在板面贴瓷砖龙骨之间的距离必须缩短到400mm。墙体每隔三块板(约3.6mm左右)必须留有一条伸缩缝。
    8. Ceramic tile on decorative surface: when installing in wet areas such as bathroom, toilet, kitchen and basement, if it is necessary to paste ceramic tile on the board surface, the distance between keels must be shortened to 400mm. There must be an expansion joint every three slabs (about 3.6 mm) of the wall.
    9.隔音墙体:如需墙体有较高的隔音效果,必须要求墙体和板材结合紧密密闭,再向空墙内填充矿棉,如龙骨两面采用两种不同厚度的板时,隔间效果更佳。
    9. Sound insulation wall: if the wall is required to have high sound insulation effect, the wall and plate must be tightly sealed, and then the empty wall shall be filled with mineral wool. If two different thickness plates are used on both sides of the keel, the effect of the compartment is better.
    10.抗冲击墙体:建议您选用8mm以上的防火板或加一层板,二张板须用长一些的螺丝钉加固。这种方法可增强抗冲击、隔热、隔音效果和防火性能。
    10. Anti impact wall: it is recommended that you choose fire-proof board of more than 8mm or add one layer of board, and the two boards should be reinforced with longer screws. This method can enhance the impact resistance, heat insulation, sound insulation and fire performance.